Skip to main content

Table 2 Influence of rotational movements on coordinate differences of the maxilla between CW and VMS

From: Comparison of manual and virtual model surgery for wafer fabrication in maxillary repositioning: an in vitro study

Types of

rotational movements

Transverse (Δx)

Anteroposterior (Δy)

Vertical (Δz)

pitch

Absence

0.49 ± 0.41

1.01 ± 1.00

0.50 ± 0.26

Presence

0.71 ± 0.54

0.99 ± 0.77

0.85 ± 0.37*

roll

Absence

0.36 ± 0.26

0.68 ± 0.53

0.72 ± 0.37

Presence

0.78 ± 0.56*

1.21 ± 0.98

0.71 ± 0.38

yaw

Absence

0.34 ± 0.23

0.57 ± 0.28

0.57 ± 0.30

Presence

1.04 ± 0.51*

1.64 ± 1.05

0.93 ± 0.36*

  1. p < 0.05 was considered statistically significant. Asterisks (*) indicate statistically significant differences compared to the group without rotational movements. CW, conventionally fabricated wafer; VMS, virtual model surgery